Prius Century Gold Low Air Loss Alternating Pressure Mattress System

SKU: CenturyGold

✔️ Free Shipping

✔️ Please Allow 7-12 Business Days for Delivery

✔️ Better Rest, Better Care

✔️ Manufacturer's Warranty

Price:
Sale price$2,311.94
Amazon American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Century Gold™ Alternating Pressure Mattress System with True Low Air Loss

The Century Gold Alternating Pressure Mattress System is a therapeutic support surface designed to help prevent and treat pressure ulcers in patients across a wide range of clinical care settings. Featuring alternating pressure therapy combined with true low air loss technology, this mattress system promotes continuous pressure redistribution while helping manage heat and moisture at the skin level.

It is ideal for patients at risk of developing pressure injuries as well as those with existing stage 1, 2, 3, or 4 pressure ulcers. Built with caregivers in mind, the Century Gold mattress system is easy to operate, reliable, and cost-effective, making it a practical solution for hospitals, long-term care facilities, rehabilitation centers, and home healthcare environments.

Front Right Side View Of The Prius Century Gold Low Air Loss Alternating Pressure Mattress System With Master Control Unit

Smart Pressure Relief Designed for Comfort, Safety & Caregiver Efficiency

  • Rapid Deflation for Emergencies: Fully deflates in under 20 seconds, allowing quick patient access, transport, or CPR response.
  • Easy Side Rail Access: Deflatable safety side air rails simplify patient entry and exit while maintaining support when inflated.
  • Customizable Alternating Cycle Times: Choose from 10, 15, 20, or 30-minute cycles to tailor pressure therapy to individual patient needs.
  • 2-in-1 Alternating Therapy Mode: Combines effective pressure redistribution with enhanced comfort. Advanced pressure mapping helps reduce high-risk pressure points by evenly distributing body weight.
  • Interchangeable, Easy-Clean Air Cells: Designed for fast removal and cleaning to support infection control and reduce bacterial growth.
  • Therapeutic 8” Air Bladders: Deep air cells deliver 2-in-1 alternating pressure therapy with On-Demand True Low Air Loss for superior moisture management.
  • High Weight Capacity: Supports patients up to 750 lbs., offering exceptional durability and inclusive patient care.
  • Power Outage Protection: Sealed system design keeps air cells inflated during power loss to maintain continuous patient support.
  • Integrated Air-Filled Side Rails: Enhances patient safety and helps reduce fall risk without compromising comfort.
  • Fowler Mode Support: Automatically increases mattress pressure when the head of the bed is raised, preventing bottoming out and improving stability.
  • Alarm Mute Function: Allows caregivers to silence system failure, power failure, and low-pressure alarms for quieter care environments.
  • On-Demand Safety & Climate Control: Deploy raised side rails when needed and activate True Low Air Loss therapy instantly for effective moisture and skin microclimate management.
  • Built-In Cable Management: Keeps electrical cords safely off the floor to reduce trip hazards and improve caregiver workflow.
  • CPR Quick-Release System: Rapidly deflates the mattress in under 20 seconds for emergency CPR situations.
Left Side View Of The Prius Century Gold Low Air Loss Alternating Pressure Mattress System With Master Control Unit

Master Control Unit Specifications

Dimensions (LxWxH) 15.5 x 7.5 x 9.5 in.
Product Weight 14.5 lbs.
Voltage Rating 110–240V
Maximum Current 5A
Frequency 60Hz
Cycle Time Options 10, 15, 20, or 30 minutes
Operating Modes Static Mode, 2-in-1 Alternation
Pressure Range 15–50 mmHg ± 6 mmHg
Air Flow Rate > 30 L/min
Electrical Safety Classification Class I, Type BF
Low Pressure Alarm Visual and audible alerts
Power Failure Alarm Visual and audible alerts
User Warranty 1 Year Warranty On Pump And Mattress
Close Up View Of The Master Control Unit For The Prius Century Gold Low Air Loss Alternating Pressure Mattress System

Mattress Specifications

Dimensions (LxWxH) 80 x 36, 42, or 48 x 10 in.
Product Weight 25.3 lbs.
Weight Capacity 500 lbs. (36” width) • 700 lbs. (42” width) • 750 lbs. (48” width)
Number of Air Cells 21 individual air cells
Cell Material Clear TPU
Cover Material Blue nylon with PU coating finish
Base Material Black polyester with PVC coating
CPR Quick Release Enables rapid mattress deflation in emergency situations
Cable Management Integrated cable management system located on the bottom cover
User Warranty 1 Year Warranty On Pump And Mattress
Front Centered View Of The Prius Century Gold Low Air Loss Alternating Pressure Mattress System

Century Gold Mattress System Brochure

Frequently Asked Questions (FAQs)

What type of therapy does the Century Gold Mattress System provide?

The Century Gold uses therapeutic alternating pressure with true low air loss, helping redistribute pressure and manage skin microclimate for patients at risk of pressure ulcers or with existing stage 1–4 ulcers.

How does the mattress support infection control and cleaning?

The Century Gold features an interchangeable air cell design that makes it easy to clean and helps minimize bacterial growth.

Can the mattress be used for higher body weights?

Yes — depending on the width selected, the Century Gold can support up to 750 lbs, providing bariatric support and durability.

What happens to the mattress air cells during a power outage?

The system is designed so that air cells stay inflated during a power failure, helping ensure continuous support and safety for the patient.

Are safety features like side rails included?

Yes — the Century Gold includes air-filled safety side rails to help enhance patient safety and reduce fall risk while preserving pressure therapy effectiveness.

★★★★★
★★★★★
★★★★★
★★★★★

You may also like