ObboMed OB-2680 PremiumAir Low Air Loss Mattress with Inflatable Guardrails

SKU: OB-2680

✔️ Free Shipping

✔️ Please Allow 4-8 Business Days for Delivery

✔️ Care-Driven Design

✔️ Manufacturer's Warranty

Price:
Sale price$2,480.00
Amazon American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

ObboMed OB-2680 PremiumAir Therapeutic Pressure Relief Mattress

The ObboMed OB-2680 PremiumAir Low Air Loss Mattress delivers advanced pressure relief, airflow, and patient safety for long-term care. Designed with cone-shaped air cells and adjustable self-lateral rotation, it promotes circulation, reduces moisture, and helps prevent pressure ulcers.

Integrated inflatable guardrails enhance safety by preventing entrapment and roll-offs, making this medical-grade mattress ideal for patients with limited mobility, paralysis, or extended bed rest in home or clinical settings.

Front Centered View Of The ObboMed OB-2680 PremiumAir Low Air Loss Mattress with Inflatable Guardrails Shown In The Flat Position

Advanced Therapeutic Design for Total Patient Care, Safety, and Comfort

  • Patented Bed Pan: Equipped with the “Easy Go” bedpan function. Operated by a single button. Creates a recessed opening in 20 seconds for bedpan placement. Reduces patient movement and caregiver workload.
  • Patented Inflatable Guardrails: Inflatable guardrails provide strong support. Operated by a single button. Protects patients from falling out of bed. Avoids bruises associated with metal guardrails.
  • 15° Self-lateral Rotation: Utilizes cone-shaped air cells for 15-degree self-lateral rotation. Alternating pressure therapy redistributes weight and stimulates blood flow. Helps prevent bedsores and nourishes the skin.
  • Sinking Feature + Centralization: Cone-shaped air cells create a sinking feature, lowering the mattress surface by up to 5 inches. Maintains patient centralization during 40-degree rotations. Creates a 9-inch soft barrier for patient safety while allowing caregiver access.
  • 15°/25°/40° Multiple Rotation Angles: Offers 15°, 25°, and 40° rotation angles. Meets varying patient needs and increases activity levels. Helps expel lung phlegm, reduces lung infections, and improves physical therapy.
  • Fowler And Seating: Increases support in the seat/torso section when the bed's head is raised. Prevents patients from “bottoming out.”
  • Dynamic Low Air Loss: Provides 16 liters per minute of low air loss therapy. Removes humidity and transfers moisture and heat away from the skin. Maximizes comfort and support for patients with stage 1-4 pressure ulcers.
  • Cell-on-Cell Mattress Design: 24-hour power outage protection prevents bottoming out. Bottom layer remains inflated during power failure if the air hose is connected. Control unit on the footboard manages all functions.
Front Left Side View Of The ObboMed OB-2680 PremiumAir Low Air Loss Mattress with Inflatable Guardrails Shown In The Flat Position

ObboMed OB-2680 Mattress Cover Features

  • Designed to minimize friction and shearing of the skin
  • Vapor permeable to facilitate moisture removal into the airflow away from the mattress
  • Perspiration vacates through the mattress cover surface and/or the patient’s bed boundary
  • Liquid resistant, Fireproof
  • Latex, lead, and mercury-free
  • Below the cover layer, vapor flows out with the Low Air Loss Feature to lower humidity under the patient while simultaneously transferring away moisture and heat
  • Air cells are composed of a combination of thermoplastic polyurethane and nylon (TPU) and airtight with high-frequency, heat sealing and are liquid proof and machine washable
Close Up View Of The Mattress Cover For The ObboMed OB-2680 PremiumAir Low Air Loss Mattress with Inflatable Guardrails

ObboMed OB-2680 Specifications

Mattress Dimensions (LxWxH) 84 x 36 x 17 in.
Pump 30 LPM
Weight Capacity 450 lbs.
Control Unit Weight 13 lbs.
Mattress Weight 38 lbs.
Unit Package Weight 61 lbs.
Unit Package Dimensions (LxWxH) 18.5 x 18.5 x 43.3 in.
User Warranty 60 Day Manufacturer Warranty
Front Left Side View Of The ObboMed OB-2680 PremiumAir Low Air Loss Mattress with Inflatable Guardrails Shown In The Fowler Position

ObboMed OB-2680 PremiumAir Low Air Loss Mattress with Inflatable Guardrails Brochure

Frequently Asked Questions (FAQs)

How does the patented bedpan feature work, and who is it designed for?

The OB-2680 features a patented “Easy Go” bedpan system that allows caregivers to create a recessed bedpan opening at the touch of a single button. Within approximately 20 seconds, an airbag beneath the buttocks deflates to allow easy bedpan placement without moving the patient. This greatly reduces patient discomfort while minimizing physical strain and workload for nursing staff and caregivers.

What makes the inflatable guardrails safer than traditional bed rails?

The patented inflatable guardrails provide strong yet soft support that helps prevent falls without the risk of bruising commonly associated with metal rails. They can be inflated or deflated using a single-button control, offering flexible protection based on patient needs while enhancing overall comfort and safety.

How does the self-lateral rotation help prevent pressure sores and improve circulation?

The OB-2680 uses cone-shaped air cells to deliver 15° self-lateral rotation through alternating pressure therapy. This gentle, wave-like movement redistributes body weight, relieves pressure points, stimulates blood flow, and helps prevent bedsores—making it ideal for patients with limited mobility or extended bed rest.

What rotation angles are available, and what are the health benefits?

This mattress offers multiple rotation angles (15°, 25°, and 40°), including left, right, and auto-turn functions. These rotations increase patient activity, assist lung expansion and phlegm expulsion, reduce the risk of lung infections, and support physical therapy and respiratory health.

What happens if there is a power outage?

The cell-on-cell mattress design provides 24-hour power outage protection, preventing the patient from bottoming out during electrical or air loss. As long as the air hose remains connected to the control unit, the bottom layer stays inflated, ensuring continued support and safety until power is restored.

★★★★★
★★★★★
★★★★★
★★★★★