ObboMed OB-2000 StandardAir Alternating Pressure Low Air Loss Mattress

SKU: OB-2000

✔️ Free Shipping

✔️ Please Allow 4-8 Business Days for Delivery

✔️ Care-Driven Design

✔️ Manufacturer's Warranty

Price:
Sale price$898.00
Amazon American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa

Advanced Support Mattress with Low Air Loss and Pressure Relief Technology

The ObboMed StandardAir Low Air Loss Alternating Pressure Mattress delivers advanced pressure relief and skin protection for bedridden or immobile users. Its micro-perforated air cells slowly release air to reduce friction, moisture, and heat buildup, helping prevent bedsores, ulcers, and skin breakdown.

The alternating pressure system redistributes weight to relieve pressure points, while enhanced support minimizes bottoming out when the bed is elevated. With audio-visual alerts and 24-hour power outage protection, this mattress ensures safety, comfort, and improved sleep quality in home care or clinical settings.

Overhead View Of The ObboMed OB-2000 StandardAir Alternating Pressure Low Air Loss Mattress Shown In The Flat Position

Therapeutic Alternating Pressure Mattress with Dynamic Support and Skin Protection

  • Fowler And Seating: Increases support in the seat/torso section of the mattress.
  • Functionality: Prevents patients from "bottoming out" when the head of the bed is raised.
  • Dynamic Low Air Loss: 16 LPM (liters per minute) air flow to remove humidity and transfer moisture and heat away from the patient's skin. Maximizes comfort and support for adults with stage 1-4 pressure ulcers.
  • Power Outage Protection: Prevents bottoming out during power failures; the bottom layer stays inflated if the air hose is connected to the control unit. Control unit located on the footboard manages all functions.
  • Cover Minimizes Friction And Shearing: Reduces skin damage.
  • Vapor Permeable: Facilitates moisture removal.
  • Perspiration Management: Perspiration vacates through the cover surface.
  • Material Qualities: Liquid resistant, fireproof, latex-free, lead-free, mercury-free.
  • Low Air Loss Feature: Reduces humidity under the patient.
  • Air Cells: Made from thermoplastic polyurethane and nylon; liquid-proof and machine washable.
Front Left Side View Of The ObboMed OB-2000 StandardAir Alternating Pressure Low Air Loss Mattress Shown In The Flat Position

ObboMed OB-2000 Mattress Cover Features

  • Designed to minimize friction and shearing of the skin
  • Vapor permeable to facilitate moisture removal into the airflow away from the mattress
  • Perspiration vacates through the mattress cover surface and/or the patient’s bed boundary
  • Liquid resistant, Fireproof
  • Latex, lead, and mercury-free
  • Below the cover layer, vapor flows out with the Low Air Loss Feature to lower humidity under the patient while simultaneously transferring away moisture and heat
  • Air cells are composed of a combination of thermoplastic polyurethane and nylon (TPU) and airtight with high-frequency, heat sealing and are liquid proof and machine washable
Front Left Side View Of The ObboMed OB-2000 StandardAir Alternating Pressure Low Air Loss Mattress Shown In The Chair Position

ObboMed OB-2000 Specifications

Mattress Dimensions (LxWxH) 80 x 36 x 9 in.
Pump 25 LPM
Weight Capacity 450 lbs.
Control Unit Weight 8.8 lbs.
Mattress Weight 15.5 lbs.
Unit Package Weight 28 lbs.
Unit Package Dimensions (LxWxH) 21 x 18.5 x 20.5 in.
User Warranty 60 Day Manufacturer Warranty
Front Left Side View Of The ObboMed OB-2000 StandardAir Alternating Pressure Low Air Loss Mattress Shown In The Flat Position With Descriptive Text

Frequently Asked Questions (FAQs)

What is the Fowler/Seating function and how does it help?

The Fowler/Seating feature increases support in the seat and torso section of the mattress. It helps prevent patients from “bottoming out” when the head of the bed is raised, ensuring safe and comfortable positioning for sitting or semi-upright postures.

How does the Dynamic Low Air Loss (LAL) system work?

The OB-2000 mattress features Dynamic Low Air Loss therapy, which provides 16 liters per minute of airflow. This system removes humidity, moisture, and heat from the patient’s skin, helping prevent bedsores and pressure ulcers while maximizing comfort and support for adults with stage 1–4 pressure injuries.

What happens during a power outage?

Thanks to the cell-on-cell mattress design, the OB-2000 offers 24-hour power outage protection. If the power goes out or the air system fails, the bottom layer of the mattress remains inflated as long as the air hose stays connected to the control unit, preventing patients from bottoming out.

Is the mattress safe and easy to clean?

Yes. The mattress cover is liquid-resistant, fireproof, and free from latex, lead, and mercury. It is designed to minimize friction and shearing on the skin while allowing moisture and perspiration to escape through the cover. The air cells are made from thermoplastic polyurethane (TPU) and nylon, are liquid-proof, airtight, and machine washable.

What are the dimensions and weight capacity of the OB-2000?

The mattress measures 80” L x 36” W x 9” H (203cm x 91cm x 23cm) and supports up to 450 lbs (200 kg). The control unit weighs 8.8 lbs (4 kg), and the mattress itself weighs 15.5 lbs (7 kg), making it easy to handle, transport, and install.

★★★★★
★★★★★
★★★★★
★★★★★

You may also like